COOL-FIT 2.0

As a pre-insulated 3-in-1 piping system for chilled water, COOL-FIT 2.0 is a corrosion and condensation-free solution designed for a variety of buildings and applications.

A mainstay of the GF Piping Systems product range, COOL-FIT 2.0 is a plastic chilled-water pre-insulated piping system that is desiged not to corrode or be affected by the formation of condensation. The rapid installation time and high energy efficiency make this system a prime option for building owners, general contractors and planners as part of commercial/residential construction, data center design and process cooling applications.

Benefits

30% Higher Thermal Energy Efficiency

The system’s innovative plastic design minimizes pressure losses and keeps thermal conductivity low for more energy efficiency than metal piping alternatives.

50% Faster Installation

The 3-in-1 pipe, insulation and jacket design paired with electrofusion jointing halves installation time, thereby reducing on-site work and labor costs.

100% Corrosion-Free

Protected against corrosion and condensation, with minimal maintenance required, COOL-FIT 2.0 is ideal for industrial cooling applications.

Minimal Environmental Impact

COOL-FIT 2.0 minimizes CO2 emissions and reduces energy loss by 35% on average compared to metal piping systems post-insulated with rubber-based foam.

How to Install

COOL-FIT 2.0 System

Learn how to easily install our COOL-FIT 2.0 system. The procedure takes just a few minutes and the GF Piping Systems MSA fusion devices ensure the quality of the joints.

Please accept all cookies to view the youtube video content.

COOL-FIT 2.0 Push System

The COOL-FIT 2.0 Push System simplifies planning and increases speed of installation through ready to install pieces, straight from the box, without the need/delay/cost of an insulation company.

Please accept all cookies to view the youtube video content.

COOL-FIT 2.0 Weld-in port

The COOL-FIT 2.0 Weld-in port enhances the capabilities of the COOL-FIT piping system by simplifying the installation of additional sensors and branches across multiple pipe sizes. 

Please accept all cookies to view the youtube video content.

Applications

Industrial Air Conditioning

An ambient work environment for the employees and stable temperatures for machinery help to sustain uninterrupted and efficient production processes.

Air Conditioning in Cruise Ships

Condensation-free air conditioning plays a vital role in onboard accommodation as it helps to have a healthy and pleasant atmosphere concerning temperature and humidity. 

Air Conditioning in Buildings

Uninterrupted air conditioning ensures a comfortable ambient environment at workplaces, residential buildings and hospitals. 

Process Cooling

Production processes require stable temperatures for machinery. Reliable and maintenance-free cooling systems help to make production more efficient.

Success Stories

Air conditioning

COOL-FIT 2-0 Reference Case EN - How pre-insulated plastic piping future-proofs your Air Conditioning system

COOL-FIT 2-0 Reference Case EN - How pre-insulated plastic piping future-proofs your Air Conditioning system

[ 10 MB / PDF ]
Download

The fast track to sustainable cooling in battery testing facility

COOL-FIT Reference Case EN - Voltavision

COOL-FIT Reference Case EN - Voltavision

[ 301 KB / PDF ]
Download

GF Piping Systems uses COOL-FIT for offices and training center

Efficient cooling for global headquarters

Efficient cooling for global headquarters

[ 2 MB / PDF ]
Download

Synergy Packaging replaces copper to pre-insulated plastic system for both exising and new facilities

Efficient cooling for recycled plastic packaging manufacturer

Efficient cooling for recycled plastic packaging manufacturer

[ 2 MB / PDF ]
Download

COOL-FIT: GF Machining Solutions installs COOL-FIT in Biel

Highly efficient production

Highly efficient production

[ 3 MB / PDF ]
Download

"Porta Samedan" shopping mall, Switzerland

Keeping cool in summer, staying warm in winter

Keeping cool in summer, staying warm in winter

[ 3 MB / PDF ]
Download

Sustainable production of plastic components

Krebs & Co COOL-FIT 2.0 - Reference Case EN

Krebs & Co COOL-FIT 2.0 - Reference Case EN

[ 628 KB / PDF ]
Download

Label printing plant: "D.E.S", Landau (Palatinate region), Germany

Perfect printing

Perfect printing

[ 4 MB / PDF ]
Download

Innovative piping solutions for the brewing industry

Reference Case: Efficient cooling for your sustainable brewery

Reference Case: Efficient cooling for your sustainable brewery

[ 6 MB / PDF ]
Download

Georg Fischer Global Head Office, Schaffhausen, Switzerland

Reliable cooling, installed efficiently and safely

Reliable cooling, installed efficiently and safely

[ 2 MB / PDF ]
Download

SENFA installs COOL-FIT for mask production

Stay cool in the fight against COVID-19

Stay cool in the fight against COVID-19

[ 3 MB / PDF ]
Download

COOL-FIT 2.0: GF Piping Systems installs COOL-FIT in Schaffhausen production plant

Sustainable process cooling

Sustainable process cooling

[ 2 MB / PDF ]
Download

Our Portfolio

Downloads

37 results

Name

COOL-FIT 2.0/4.0 Flange Adaptor Test Report 2.2 EN/DE

COOL-FIT 2.0/4.0 Flange Adaptor Test Report 2.2 EN/DE

COOL-FIT 2.0/4.0 Flange Adaptor Test Report 2.2 EN/DE

[ 25 KB / PDF ]
Download

Assembly Instructions COOL-FIT 2.0 Push System Ball Valve

Assembly Instructions COOL-FIT 2.0 Push System Ball Valve

Assembly Instructions COOL-FIT 2.0 Push System Ball Valve

[ 2 MB / PDF ]
Download

Assembly Instructions COOL-FIT 2.0 Push System Fittings

Assembly Instructions COOL-FIT 2.0 Push System Fittings

Assembly Instructions COOL-FIT 2.0 Push System Fittings

[ 2 MB / PDF ]
Download

Assembly Instructions COOL-FIT 2.0 Push System d16-d20 flow control valve

Assembly Instructions COOL-FIT 2.0 Push System d16-d20 flow control valve

Assembly Instructions COOL-FIT 2.0 Push System d16-d20 flow control valve

[ 2 MB / PDF ]
Download

Assembly Instructions COOL-FIT 2.0/4.0 Push System Transition Fitting

Assembly Instructions COOL-FIT 2.0/4.0 Push System Transition Fitting

Assembly Instructions COOL-FIT 2.0/4.0 Push System Transition Fitting

[ 2 MB / PDF ]
Download

Assembly Instructions COOL-FIT 2.0/4.0 Push System d25-d32 Flow Control Valve

Assembly Instructions COOL-FIT 2.0/4.0 Push System d25-d32 Flow Control Valve

Assembly Instructions COOL-FIT 2.0/4.0 Push System d25-d32 Flow Control Valve

[ 2 MB / PDF ]
Download

Assembly Instructions Fixed Point COOL-FIT 2.0 / COOL-FIT 4.0

Assembly Instructions Fixed Point COOL-FIT 2.0 / COOL-FIT 4.0

Assembly Instructions Fixed Point COOL-FIT 2.0 / COOL-FIT 4.0

[ 1 MB / PDF ]
Download

Assembly instructions COOL-FIT 2.0-4.0 Weld-in port PE spigot

Assembly instructions COOL-FIT 2.0-4.0 Weld-in port PE spigot

Assembly instructions COOL-FIT 2.0-4.0 Weld-in port PE spigot

[ 2 MB / PDF ]
Download

Assembly instructions COOL-FIT 2.0-4.0 Weld-in port PE/iFIT

Assembly instructions COOL-FIT 2.0-4.0 Weld-in port PE/iFIT

Assembly instructions COOL-FIT 2.0-4.0 Weld-in port PE/iFIT

[ 2 MB / PDF ]
Download

Assembly instructions COOL-FIT 2.0/COOL-FIT 4.0 Fixed point kit for high forces (DE, EN)

Assembly instructions COOL-FIT 2.0/COOL-FIT 4.0 Fixed point kit for high forces (DE, EN)

Assembly instructions COOL-FIT 2.0/COOL-FIT 4.0 Fixed point kit for high forces (DE, EN)

[ 2 MB / PDF ]
Download

Plan, Build, Operate

Building Technology

Building Technology

[ 127 MB / PDF ]
Download

COOL-FIT 2.0 - The Revolution for Efficient Cooling

COOL-FIT 2.0 - The Revolution for Efficient Cooling

COOL-FIT 2.0 - The Revolution for Efficient Cooling

[ 224 KB / PDF ]
Download

FAQs

For which environments is COOL-FIT 2.0 designed?

COOL-FIT 2.0 is designed for secondary cooling loops with media temperature >= 0°C and for indoor installations.

Which are the target industries and applications of COOL-FIT 2.0?

COOL-FIT 2.0 is designed for airconditioning applications in commercial buildings, for Process Cooling in Industrial applications and Data Centers as long as the media temperature stays above 0°C.

How can I realize the outoor part of a cooling loop?

COOL-FIT 2.0 is fully compatible to COOL-FIT 4.0 which is desinged for outdoor and burried installations. There is a conversion kit available to seal the insulation of the two systems.

Which support tools are available to ensure a professional pipe systems design?

GF provides detailed planning fundamentals files, additionally the digital "Cooling Toolbox" allows to briefly proof, calculate and define behaviours like jointing times, energy savings, weights, pressure losses and many more.

Speak to an Expert.